2026-11-20
Five 400QJ210-300 submersible deep well pumps manufactured by SLAPK have successfully passed the customer’s on-site tests. Each pump is equipped with a 300 kW, three-phase, 3 kV, 50 Hz submersible motor.
According to the latest customer feedback, two of the five pumps have already been placed into service and are performing well.
The customer needed large deep well pumps for a high-head water-supply application. The confirmed pump configuration was:
For equipment of this size, successful operation depends on more than the pump’s rated flow and head. The hydraulic section, motor, cable, cooling design and site power supply must work together.![]()
![]()
The customer provided a signed commissioning record for one of the pumps. During the recorded test, the pump was installed at a depth of 244 metres, while the water level shown in the record was 184.54 metres.
The ultrasonic flowmeter readings increased from 226 m³/h at the beginning of the observation period to 236 m³/h at the final recorded point. During these readings, the current remained stable at 64 A. The recorded supply voltage was 3.2 kV, and the motor insulation resistance was 250 MΩ.
These figures describe the conditions during this particular commissioning test. They should not be treated as guaranteed performance at every possible water level or pipeline condition. Actual operation is affected by the dynamic water level, system resistance, outlet pressure and power-supply conditions.
The customer confirmed that all five pumps passed on-site testing successfully. The feedback email also stated that two units were already operating and that their operating indicators were excellent.
A noticeable feature of these pumps is the extended section at the lower end of the motor. This is a specially designed cooling section, not an additional pump stage.
A 300 kW submersible motor produces considerable heat during operation. The extended structure increases the available heat-transfer area and helps the surrounding water carry heat away from the motor. This supports stable motor temperature control under the approved installation and operating conditions.
The cooling section must remain properly submerged, and the water path around the motor must not be blocked. Pump setting depth, operating water level and well diameter should therefore be checked before installation.
Before delivery, the five pump sets were assembled and inspected at our factory. For a high-voltage deep well pump project, our checks include the pump and motor connection, cable arrangement, insulation condition, rotation, external finish and overall dimensions.
The factory photos show the five large pump units during assembly and preparation. The extended cooling sections were installed as part of the motor configuration before shipment.
This project demonstrates the successful application of five 400QJ210-300 high-head submersible deep well pumps with 300 kW, 3 kV motors.
All five units passed the customer’s site tests. Two pumps have entered service, and the customer reports that they are operating well. The commissioning record also provides clear operating data for flow, current, voltage and insulation resistance.
For a similar deep well project, please send us the required flow, total dynamic head, well depth, static and dynamic water levels, casing internal diameter, pump setting depth, voltage, frequency and daily operating hours. SLAPK can select the pump, motor and cooling configuration for the actual site conditions.
Send your inquiry directly to us