When a customer asks us for a “complete QJ pump set,” the request sounds clear, but it can mean different things to different buyers.
One customer may expect only the pump and motor. Another may also expect the cable, control panel, rising main and valves. Without a confirmed supply scope, important equipment may be missing when the pump arrives.
At SLAPK, we prefer to list every major item separately in the quotation. This allows the customer to see what is included, what is optional and what must be purchased locally.
The expression “complete set” is not a precise technical specification. Its meaning depends on the supplier, project and contract.
For a QJ deep well pump, the core equipment normally consists of the hydraulic pump section and a matched submersible motor. However, the complete pumping system also needs electrical, piping, control and installation components.
Some components may already be available at the site, while others come from the pump manufacturer or local contractors. Buyers should not assume every accessory is included because the quotation uses the word “set.”
The safest approach is to check the itemized supply list.
The hydraulic section is the upper part of the QJ submersible well pump. It contains the multistage pump components that produce flow and head.
Depending on the selected model, the hydraulic section can include:
QJ hydraulic components are produced through a casting process. The number of stages is selected according to the required total dynamic head, while the hydraulic family is selected according to the required flow.
The model, material, stage quantity, outlet connection and dimensions should appear in the technical offer. “QJ pump head” does not confirm the complete configuration.
The hydraulic pump cannot operate without a suitable submersible motor. The motor must match the pump in power, speed, shaft connection, outside diameter and thrust capacity.
The motor specification should confirm:
Changing the voltage or frequency after ordering requires the motor, cable and controls to be checked again. The installation team must also follow the supplied motor preparation instructions.
The pump and motor must be mechanically connected and correctly aligned. Depending on the design and shipping arrangement, the connection can involve a coupling, connecting bolts, mounting flange and shaft interface.
Smaller units may be shipped as an assembled pump and motor. Larger or longer QJ pumps may be packed in separate sections to make transportation and lifting safer. In that case, site assembly must follow the manufacturer’s drawing and instructions.
The quotation should state whether the pump and motor are shipped assembled or separately.
A submersible motor normally has a factory lead, but this does not always mean that the complete downhole cable length is included.
The route may include the factory lead, downhole extension, surface cable to the panel and cable to the power source.
The extension cable should be selected from the motor current, voltage, phase, total route length and permitted voltage drop. The downhole section must also be suitable for continuous immersion.
Buyers should confirm the cable material, conductor size, number of cores, total length and whether a waterproof underwater splice kit is included. Writing only “with cable” in a purchase order is not enough.
A control panel is often optional rather than part of the basic pump-and-motor price.
The correct panel depends on the motor power, voltage, phase and starting method. It may include functions such as:
We also need to know whether power comes from a utility supply, transformer, generator or solar system.
The quotation should identify the panel type and protection functions. If the panel is not included, this should also be stated clearly.
The rising main carries water from the pump outlet to the wellhead. It is normally a separate supply item unless it is specifically included in the project quotation.
Its selection depends on:
Do not select the pipe only because it matches the outlet. Check velocity, friction loss, pressure and mechanical load.
Because pipe standards and local installation practices vary, many customers purchase the rising main locally. We can provide the pump outlet size and dimensional information needed for the connection.
The complete surface discharge arrangement may require an external check valve, isolation valve, pressure gauge, flowmeter, air valve or other fittings.
The arrangement depends on the system, including pressure rating, orientation, flow area and valve-closing behaviour.
Buyers should also confirm whether the selected pump contains an internal non-return valve and whether the system designer requires an additional valve above the pump or at the wellhead.
These surface components are not automatically included with the QJ pump.
The power cable must be supported along the rising main so that it does not hang freely or rub against the casing.
Depending on the project, installation accessories may include:
These items must fit inside the casing with the pump, pipe couplings and cable. The largest component may be a splice or coupling rather than the pump body.
Before shipment, the buyer may also require:
Spare parts are normally included only when listed. For remote projects, discuss critical spares before shipment.
To define the correct QJ pump and supply scope, please send us:
We will separate the quotation into the pump, motor and accessories. This prevents differences in supply scope from being mistaken for price differences.
Before approving a QJ pump quotation, ask the following:
A complete QJ system requires more than a model and motor power. The pump, motor, cable, controls, pipe and valves must work together.
However, not every component is automatically included in the pump price. The actual supply scope must be confirmed in the quotation and contract.
At SLAPK, we recommend using an itemized list instead of relying on the words “complete set.” Send us your well data, required duty point, electrical supply and accessory requirements. We will prepare a clear QJ pump proposal showing what is included, what is optional and what should be sourced locally.
Send your inquiry directly to us