Place of Origin:
China
Brand Name:
SLAPK
Certification:
CE, ISO9001
Model Number:
200QJ20-216/16
Our 200QJ20-216/16 is a 16-stage deep well submersible pump for farmland irrigation and clean water supply. A 25 kW motor drives it at a nominal flow of 20 m³/h and a nominal head of 216 m. The hydraulic parts are cast iron HT200, the standard build for clean water with no corrosive tendency.
Water enters at the inlet section and is lifted stage by stage through the impellers and diffusers before leaving through the 2.5 inch outlet. The stacked stage design lets the pump sit below the water surface in the borehole, so it does not need suction lift and holds its prime when it is installed within the submergence conditions specified for the selected assembly.
The 200QJ20 family covers 30 m to 405 m head at the same 20 m³/h nominal flow. If your borehole needs a different total head, you can stay within the same family and keep the same outlet size, rising main and installation method.
The main duty for this model is farmland irrigation from a borehole, where the pump lifts water into a channel or a storage tank. At 20 m³/h and 216 m the unit can run through a long irrigation shift as the water level falls, when the installation maintains the minimum submergence and motor cooling conditions specified for the selected assembly.
It is also used for general water supply from a deep well to a village, a livestock farm or a small waterworks, as long as the water is clean and non-corrosive. For brackish water, seawater, treated wastewater or water with a high chloride content, the cast iron build is not the right choice; we select a stainless steel or seawater build for those duties.
The hydraulic components are manufactured by casting. This model is supplied in cast iron as standard; stainless steel options SS304, SS316, 904L and 2507 are available on request. The material configuration is confirmed in the quotation according to the water quality and project requirements.
1. Catalog ranges and the operating point. The flow and head figures above are the catalog ranges listed for this model. The required operating point must be checked against the performance curve for the quoted configuration. The maximum catalog flow and maximum catalog head should not be combined as a guaranteed operating point.
2. Well depth and total head are different numbers. Total head is the pumping water level below the wellhead, plus the delivery elevation, plus the friction loss in the rising main and discharge pipe. Static water level, pumping water level and planned setting depth are asked for separately in the quotation request because one cannot replace another.
3. Well diameter must be checked against the drawing. The 2.5 inch figure is the discharge connection, not the outside diameter of the pump. The 200 in the model name identifies the catalogue series and must not be read as the pump outside diameter or as an unconditional minimum borehole size. We confirm the required well diameter from the installation drawing for the exact build.
The motor rating for this model is 25 kW. Please provide the supply voltage, frequency and phase. The motor rating, rated current and electrical configuration will be confirmed for the selected assembly. Performance data will correspond to the specified frequency.
Cable length and conductor size are selected according to the complete cable route, motor rating, supply voltage, voltage drop and installation requirements. The supplied cable specification will be stated in the quotation.
Each pump is built to the configuration confirmed on the order, tested at our works before packing, and released for delivery after it passes.
The quotation will specify the supplied motor lead cable, any extension cable, control equipment and accessories.
Do not run the pump dry. The installation must maintain the minimum submergence and motor cooling conditions specified for the selected assembly.
The minimum order quantity is to be confirmed in the quotation. Lead time will be stated in the quotation based on the order configuration and quantity. Warranty terms will be specified in the quotation. Packing is specified in the quotation.
1. Is cast iron suitable for my well water?
For clean, non-corrosive water, yes. If the water is brackish, salty or chemically treated, the iron parts will corrode, and we would quote a stainless steel or seawater build instead.
2. Does the pump come with a control cabinet and cable?
Not by default. The pump is quoted as the unit itself; cabinets, drives and cable are quoted according to your installation.
3. Can this pump deliver 22 m³/h at 249 m at the same time?
No. Those are catalog range limits listed for this model. The required operating point must be checked against the performance curve for the quoted configuration.
4. Can I use the same pump for a deeper well later?
Within the same family, a higher-head model can be selected if the well data supports it. Changing the setting depth changes the total head, so the model has to be rechecked rather than adjusted on site.
5. What do you need from us to quote?
The duty point, well data, supply voltage and frequency, material requirement, cable length, quantity and destination. The list below shows the items that matter most.
To select the right build and give you a firm quotation, please send us:
You can leave any item you do not know blank. We will confirm the duty point on the curve and reply with the configuration, price and lead time.
Send your inquiry directly to us